Indiacon Civil

Subjects › Water Supply Engineering › Intermediate

Sedimentation and coagulation

Intermediate Water Supply Engineering Reviewed 24 Oct 2026 2 min read

Raw surface water is turbid with silt, clay, algae and organic matter. Sedimentation tanks let heavier particles settle under gravity. Particle settling velocity follows Stokes' law for small, slow particles, rising with the square of particle size and with density difference. An ideal settling tank removes all particles whose settling velocity exceeds the surface overflow rate, the flow divided by plan area. Depth affects detention time but not, in theory, removal efficiency, which is why shallow tube settlers and plate settlers improve performance.

Fine clay and colloids settle far too slowly, because they are tiny and carry negative charges that repel each other. Coagulation neutralises those charges by adding a coagulant, usually aluminium sulphate (alum), poly-aluminium chloride or ferric salts, mixed rapidly so it disperses within seconds. Flocculation follows: gentle mixing for 20 to 40 minutes encourages destabilised particles to collide and stick into large, heavy flocs that settle readily. The velocity gradient G and its product with time, Gt, guide flocculator design.

Diagram: Indiacon original, not to scale.

The right coagulant dose depends on raw water quality and is found by jar tests, which mimic rapid mix, flocculation and settling in beakers. pH and alkalinity matter, because alum consumes alkalinity. Settled water then passes to filters. Clariflocculators combine flocculation and settling in one unit; sludge from the tank bottom is removed and treated.

Real tanks fall short of the ideal because of short-circuiting, density currents, wind and inlet turbulence, so designers use baffled inlets, uniform outlet weirs with limited weir loading and safety margins on overflow rate.

Tip

Run jar tests whenever raw water turbidity changes sharply, for example at the start of the monsoon.

Key formulas
  • Stokes: vs = g (ρs − ρw) d² / (18 μ)
  • Surface overflow rate: SOR = Q / A
  • Detention time: t = V / Q
  • Velocity gradient: G = √(P / (μ V))
Common mistake

Overdosing alum, which lowers pH, leaves residual aluminium and creates excess sludge without improving settling.

Solved example

Problem. A settling tank treats 12 MLD and must have an SOR of 30 m³/m²/day and detention of 3 hours. Find plan area and depth.

  1. Q = 12 000 m³/day; area = 12 000 / 30 = 400 m².
  2. Volume = 12 000 × 3 / 24 = 1 500 m³.
  3. Depth = 1 500 / 400 = 3.75 m.
  4. A circular tank of diameter √(400 × 4/π) = 22.6 m would suit.

Answer. 400 m² plan area, 3.75 m depth

Quick quiz

1What decides removal in an ideal settling tank?

Surface overflow rate.

2Why are coagulants needed?

To neutralise charges on colloids so they can stick into flocs.

3What test finds the coagulant dose?

The jar test.

Code note
  • CPHEEO Manual on Water Supply and Treatment (India): Central government manual for planning, design and operation of public water supply.

Clauses and documents to read

  • CPHEEO Manual on Water Supply and Treatment (sedimentation, coagulation and flocculation chapters, cited by name)
  • IS 10500:2012 (target quality)

Cited by number and clause only. We do not reproduce clause text, tables or figures (BIS Act 2016, s.10(5) and s.11). Check the current edition and amendments before use.

References and further reading

Standard texts, listed in no order of merit. We do not copy text, figures, tables or solved problems from any book; our explanations and examples are original.

  • S. K. Garg, Water Supply Engineering (Environmental Engineering Vol. I), Khanna Publishers, latest edition.
  • MWH (J. C. Crittenden et al.), Water Treatment: Principles and Design, Wiley, 3rd edition.
  • H. S. Peavy, D. R. Rowe, G. Tchobanoglous, Environmental Engineering, McGraw Hill, 1985.

Free and official sources

All references for this subject →

Found an error? Write to indiacongroupofengineers [at] gmail [dot] com. For corrections and feedback. We never ask for payment or personal details.