Indiacon Civil

Subjects › Water Supply Engineering › Intermediate

Pipe flow in networks

Intermediate Water Supply Engineering Reviewed 24 Oct 2026 2 min read

A water distribution network is a web of pipes, valves, tanks and pumps that must deliver enough water at enough pressure to every consumer at peak demand, and keep flowing during fires and breakdowns. Looped networks, in which every point can be fed from two directions, are more reliable than branched, tree-like ones.

Pipe sizing rests on head loss. As water flows, friction with the pipe wall uses up energy. The Darcy–Weisbach equation is the theoretically sound method, using a friction factor from the Moody diagram or Colebrook equation. In water supply practice, the empirical Hazen–Williams formula is widely used, with a coefficient C that depends on pipe material and age; new smooth pipes have high C, old corroded pipes much lower.

Diagram: Indiacon original, not to scale.

In a looped network, the flows must satisfy two rules: at each junction, flow in equals flow out; around each loop, the head losses add up to zero. The classic Hardy Cross method corrects assumed loop flows by successive approximation; today network software solves the whole set of equations together and also runs extended-period simulations over the daily demand cycle.

Design keeps minimum residual pressures at the farthest and highest points, limits velocities to avoid both sediment deposition and high surge, and checks fire-flow cases. India's CPHEEO manual gives recommended C values, pressures and design periods.

Tip

Use the C value for the pipe at the end of its design life, not when new.

Key formulas
  • Hazen–Williams (SI): h_f = 10.67 L Q^1.852 / (C^1.852 D^4.87)
  • Velocity: V = Q / (π D² / 4)
Common mistake

Mixing units in Hazen–Williams; the 10.67 constant is for SI units with Q in m³/s and D in m.

Solved example

Problem. Find the head loss in 1 000 m of 250 mm pipe carrying 50 L/s with C = 130, and the velocity.

  1. h_f = 10.67 × 1 000 × 0.05^1.852 / (130^1.852 × 0.25^4.87).
  2. h_f ≈ 4.32 m per 1 000 m.
  3. V = 0.05 / (π × 0.25² / 4) = 0.05 / 0.0491 = 1.02 m/s.
  4. The velocity is in the usual economical range; the loss is acceptable for a distribution main.

Answer. Head loss about 4.3 m per km; velocity about 1.0 m/s

Quick quiz

1What two rules does a looped network satisfy?

Continuity at junctions and zero net head loss around each loop.

2What happens to C as pipes age?

It falls as the bore roughens and narrows.

3Why are looped networks preferred?

Every point can be supplied from two directions.

Code note
  • CPHEEO Manual on Water Supply and Treatment (India): Central government manual for planning, design and operation of public water supply.
  • IS 10500 (India): Specification for drinking water quality.
  • EN 806 (series) (Europe): Installations inside buildings conveying water for human consumption.

Cited by number and clause only. We do not reproduce clause text, tables or figures (BIS Act 2016, s.10(5) and s.11). Check the current edition and amendments before use.

References and further reading

Standard texts, listed in no order of merit. We do not copy text, figures, tables or solved problems from any book; our explanations and examples are original.

  • S. K. Garg, Water Supply Engineering (Environmental Engineering Vol. I), Khanna Publishers, latest edition.
  • MWH (J. C. Crittenden et al.), Water Treatment: Principles and Design, Wiley, 3rd edition.
  • H. S. Peavy, D. R. Rowe, G. Tchobanoglous, Environmental Engineering, McGraw Hill, 1985.

Free and official sources

All references for this subject →

Found an error? Write to indiacongroupofengineers [at] gmail [dot] com. For corrections and feedback. We never ask for payment or personal details.