Drinking water quality
Drinking water must be safe and acceptable. Safe means free of disease-causing organisms and of chemicals at harmful levels; acceptable means clear, without odour or taste, so people do not turn to unsafe sources. Indian requirements are set in IS 10500, which lists acceptable limits and, for some parameters, permissible limits in the absence of an alternative source.
Microbiological quality is the first priority, because waterborne diseases such as cholera, typhoid and diarrhoeal illnesses kill far more people than chemical contaminants. Since testing for every pathogen is impractical, indicator organisms are used: E. coli and total coliforms should not be detectable in a 100 mL sample of drinking water. Physical parameters include turbidity, colour, taste and odour. Chemical parameters cover pH, total dissolved solids, hardness, alkalinity, chloride, sulphate, nitrate, iron and manganese, plus toxic substances such as fluoride, arsenic, lead, mercury, chromium and pesticides. Fluoride and arsenic are major natural groundwater problems in parts of India, and nitrate from fertilisers and sewage is rising.
Water safety planning manages risk from catchment to tap: protecting sources, providing multiple treatment barriers, maintaining pressure in distribution to stop contamination entering, and monitoring residual chlorine at consumer ends. Sampling frequency increases with population served. Laboratories should be accredited and results acted on.
Treatment is chosen to match the problem. Turbidity and pathogens call for coagulation, filtration and disinfection. Hardness can be reduced by lime-soda softening or ion exchange. Iron and manganese are removed by aeration and filtration. Fluoride needs activated alumina, bone char or the Nalgonda technique at small scale, and arsenic needs adsorption or coagulation-based removal with safe sludge disposal. Reverse osmosis removes most dissolved salts but wastes water and needs remineralisation.
Measure residual chlorine at the tail end of the network every day; it is the cheapest indicator that the system is protected.
Hardness as CaCO₃ = 2.5 Ca²⁺ + 4.12 Mg²⁺ (mg/L)Turbidity in NTUColiforms: per 100 mL sample
Relying on clear appearance as proof of safety; clear water can still carry pathogens and dissolved toxins.
Problem. A groundwater sample has Ca²⁺ = 64 mg/L and Mg²⁺ = 22 mg/L. Find total hardness as CaCO₃.
- From calcium: 2.5 × 64 = 160 mg/L.
- From magnesium: 4.12 × 22 = 90.6 mg/L.
- Total hardness = 250.6 mg/L as CaCO₃.
- Compare with the acceptable and permissible limits in IS 10500 before deciding on softening.
Answer. About 251 mg/L as CaCO₃
Quick quiz
1Why is microbiological quality the top priority?
Waterborne disease causes far more harm than most chemical contaminants.
2Which organism indicates faecal contamination?
E. coli.
3Name two natural groundwater contaminants important in India.
Fluoride and arsenic (also iron, salinity).
- IS 10500 (India): Specification for drinking water quality.
- CPHEEO Manual on Water Supply and Treatment (India): Central government manual for planning, design and operation of public water supply.
Clauses and documents to read
- IS 10500:2012 (drinking water specification, Tables 1 to 4 cited by number only)
- IS 3025 (various parts) (methods of sampling and test for water)
- IS 1622:1981 (bacteriological examination of water)
Cited by number and clause only. We do not reproduce clause text, tables or figures (BIS Act 2016, s.10(5) and s.11). Check the current edition and amendments before use.
References and further reading
Standard texts, listed in no order of merit. We do not copy text, figures, tables or solved problems from any book; our explanations and examples are original.
- S. K. Garg, Water Supply Engineering (Environmental Engineering Vol. I), Khanna Publishers, latest edition.
- MWH (J. C. Crittenden et al.), Water Treatment: Principles and Design, Wiley, 3rd edition.
- H. S. Peavy, D. R. Rowe, G. Tchobanoglous, Environmental Engineering, McGraw Hill, 1985.
Free and official sources
Found an error? Write to indiacongroupofengineers [at] gmail [dot] com. For corrections and feedback. We never ask for payment or personal details.