Indiacon Civil

Subjects › Earthquake Engineering › Basics

What an earthquake does to a building

Basics Earthquake Engineering Reviewed 24 Oct 2026 2 min read

An earthquake does not push a building directly. It shakes the ground, and the building's mass, trying to stay where it was, lags behind. The result is horizontal inertia forces at every floor, largest where the mass is greatest and the shaking amplified most.

How strongly a building responds depends on its natural period, the time for one free sway. Stiff low-rise buildings have short periods; tall flexible buildings have long ones. When the ground shakes near a building's period, the response grows. Soft soils amplify some periods and lengthen the shaking.

Diagram: Indiacon original, not to scale.

Codes do not ask buildings to stay elastic in a large earthquake; that would be uneconomic. Instead, the structure is designed for a reduced force and detailed to be ductile, so that chosen parts yield and absorb energy without collapse. Closely spaced ties at column ends, strong columns relative to beams, and well-anchored bars are what make that possible.

Irregular buildings concentrate damage. A soft open ground storey, a heavy water tank on the roof, or a sudden change in plan can lead to collapse even when the rest of the building is sound.

Key formulas
  • Natural period of a single-degree system: T = 2π √(m / k)
  • Inertia force F = m × a
Solved example

Problem. A water tank structure is idealised as mass 50 000 kg on a support of lateral stiffness 20 × 10⁶ N/m. Find its natural period.

  1. T = 2π √(50 000 / 20 × 10⁶) = 2π √(0.0025) = 2π × 0.05 = 0.314 s.

Answer. About 0.31 s

Quick quiz

1What generates earthquake forces in a building?

The inertia of its mass as the ground shakes.

2Why are buildings designed for less than elastic force?

Ductile detailing lets them yield safely and absorb energy.

3Name a dangerous irregularity.

An open soft ground storey.

Code note
  • IS 1893 (Part 1) (India): Criteria for earthquake-resistant design: seismic zones and how to work out earthquake forces.
  • IS 13920 (India): Ductile design and detailing of reinforced concrete structures for seismic forces.

Cited by number and clause only. We do not reproduce clause text, tables or figures (BIS Act 2016, s.10(5) and s.11). Check the current edition and amendments before use.

Related videos

Short

Column end confinement zone

Closer ties near column ends help a column survive earthquake shaking. IS 13920.

Watch on YouTube →

Short

Shear wall basics

Why some walls are built to resist sideways load. IS 13920.

Watch on YouTube →

References and further reading

Standard texts, listed in no order of merit. We do not copy text, figures, tables or solved problems from any book; our explanations and examples are original.

  • A. K. Chopra, Dynamics of Structures, Pearson, latest edition.
  • T. Paulay, M. J. N. Priestley, Seismic Design of Reinforced Concrete and Masonry Buildings, Wiley, 1992.
  • P. Agarwal, M. Shrikhande, Earthquake Resistant Design of Structures, PHI Learning, latest edition.

Free and official sources

All references for this subject →

Found an error? Write to indiacongroupofengineers [at] gmail [dot] com. For corrections and feedback. We never ask for payment or personal details.